A REACH SVHC declaration for vanity hinges and slides is only as good as its specifics: which Candidate List revision it was checked against, whether the assessment was made at the level of each homogeneous component — the roller, the plating, the grease — and an explicit statement of what was found, not a blanket “REACH compliant.” Most declarations buyers receive fail at least one of those tests, and most buyers never notice because the document looks official. Before you file the next declaration away, here is what a complete one contains, which substances deserve pushback, and how to keep the paperwork current as the Candidate List grows.
Key Takeaways
- A usable SVHC declaration names REACH Article 33, the Candidate List revision checked, and a per-component result — never just ‘REACH compliant’.
- The 0.1% w/w threshold is assessed per homogeneous article: roller, plating and grease can each be separate articles in one hinge.
- Re-request declarations on list updates and material changes; lead, cadmium, Cr(VI) and listed phthalates in accessible parts deserve written pushback.
What Article 33 Actually Requires
The obligation comes from Article 33 of REACH — Regulation (EC) No 1907/2006 — which you can read in full on the EU’s official REACH regulation page. In plain terms: if an article contains a Substance of Very High Concern from the Candidate List in a concentration above 0.1% weight by weight, the supplier must communicate that fact to the customer, with enough information to allow safe use of the article. Two details in that sentence decide whether a declaration is real. First, the 0.1% threshold is assessed per article — and in REACH terms, a hinge’s nylon roller, its steel body, and its plating can each be separate articles — not averaged across the whole vanity. Second, the duty is to communicate presence, not to be SVHC-free: a substance above the threshold is not automatically illegal, but it must be named, quantified and explained.
That distinction is why “REACH compliant” is a meaningless sentence in a declaration. Compliance can mean registration, restrictions, authorization or communication — any one of several things — and none of them tells you whether a Candidate List substance is present in the part. A usable declaration says one of two things explicitly: either that no Candidate List SVHC is present above the threshold in any component, or that specific substances are present, named, with their concentration and location in the part.
The Anatomy of a Usable Declaration
When a hardware supplier sends a declaration for hinges, slides or handles, check it against this structure before filing it:
- Identification: the supplier’s legal name and address, the exact part numbers, finishes and revision dates covered — and whether the document covers the complete hinge or slide or only selected materials.
- Regulatory basis: a citation of REACH Article 33 and, critically, the date or revision of the Candidate List the assessment was made against.
- The result: a clear “none present above 0.1% w/w” statement, or a table of every SVHC found with substance name, EC or CAS number, concentration, and the exact material or component where it sits — a coating, a plastic bumper, the grease, the plating.
- Provenance: confirmation that the supplier collected the information from its own upstream suppliers of steel, plastics, coatings and lubricants, and whether the conclusion comes from supplier data or from testing.
- Reviews: the date of the supplier’s last review, so you can judge whether the document is current or a photocopy of history.
The Candidate List dating matters more than most buyers realize. The list is updated roughly twice a year, and a declaration checked against a revision from three years ago says nothing about substances added since. For bathroom furniture with metal hardware, the practical discipline is to re-request declarations whenever the list is updated and your program’s parts are affected — suppliers who maintain real compliance systems can re-issue quickly, because they track their own bills of materials. Our guide to verifying cabinet hardware quality covers the parallel discipline on the performance side; the two together make up a hardware file a European auditor will actually accept.
Substances That Deserve Pushback
Not every SVHC is a crisis, but some substances in vanity hardware are worth a written explanation, a quantified concentration and a substitution plan. Lead and its compounds are the classic: they can hide in brass alloys, free-cutting steel, solder, pigments and stabilizers, and they matter most where the part is touched often — a handle, a knob, a sliding rail a guest’s fingers find. Cadmium in plating or pigments is a stronger red flag still, because in ordinary furniture hardware there is rarely a good technical reason for it. Hexavalent chromium compounds are a different question from ordinary stainless steel or trivalent decorative chrome: the declaration should say which process chemistry is used, because chromate passivation and Cr(VI) coatings are exactly the kind of detail a one-line certificate hides.
On the plastics side, the listed phthalates — DEHP, BBP, DBP and DIBP — are the ones to chase in soft rollers, bumpers, PVC parts and flexible coatings, because they sit in accessible flexible components and non-phthalate formulations are widely available. Short-chain chlorinated paraffins and certain legacy brominated flame retardants occasionally appear in older rubber, sealants or specialty plastics; substitution is usually straightforward, so a refusal to substitute is itself information. And treat “PFOA-free” or “PFAS-free” marketing claims as separate from the SVHC question entirely — if the hardware carries fluoropolymer coatings or specialty lubricants, ask which fluorinated substances are present and whether any are on the Candidate List, rather than accepting a logo. For buyers also shipping into California, the same component-level thinking drives Prop 65 warnings for vanity imports; the two regimes ask similar questions with different paperwork.

Read the Declaration Like an Auditor
A quick read-through separates the useful declarations from the decorative ones in about two minutes. The tell-tale phrases are consistent across the industry. “We hereby declare that our products are REACH compliant” — decorative: no result, no threshold, no list date. “Based on information provided by our suppliers” without naming which materials or when — decorative: provenance too vague to verify. “SVHC-free” with no qualification — suspicious: either the supplier truly tracks every coating, grease and polymer in every variant, which deserves a follow-up question about how, or the sentence was written by a template. By contrast, the useful document names the regulation and article, dates the Candidate List revision, states a per-component result, and identifies who in the supplier’s organization signed it. Where it reports a substance, it gives the CAS number, the concentration or range, and the component — the fields that feed downstream obligations and your own customer declarations without re-engineering.
Two audit habits make the review faster every round. Compare against the previous revision: a declaration that changed nothing while the Candidate List grew is either a lazy template or a genuine no-change result, and one question to the supplier tells you which. And sample the technical claims: pick one part in the declaration, ask the supplier to walk you through where its assessment came from — the steel mill’s data, the plater’s declaration, a test report — and note how specific the answer is. Suppliers with real systems answer in one email; suppliers with marketing departments answer in three weeks with another template. That response pattern is itself a data point for the next sourcing round, and it weighs more than the wording of any single document.
Keep the File Alive, Not Archived
The most common failure is not a bad declaration — it is a good declaration treated as a one-time exhibit. A working REACH file for a vanity program has three moving parts. First, a declaration register: one row per part number, showing the declaration date, the Candidate List revision it was checked against, and the next review due. Second, a change trigger: when the Candidate List updates, or when the supplier changes a plating line, a plastics source or a lubricant, the affected declarations are re-requested — this connects directly to your supplier’s engineering change process, which our guide to UKCA and CE marking for bathroom cabinets discusses in the wider compliance context. Third, an acceptance rule: what your team does when a declaration is missing a Candidate List date, or says “compliant” without a result, or covers “materials” instead of parts. Write the rule down, and the file maintains itself.
Where declarations report SVHCs above the threshold in articles supplied to the EU market, additional duties can apply — including notification to ECHA’s SCIP database for relevant articles — which is one more reason the substance, concentration and component location in the declaration must be specific enough to act on. A declaration that cannot feed those fields is not finished paperwork; it is a promise that someone, somewhere, will have to reconstruct the data under deadline.
Sourcing Vanity Hardware for the EU?
Send us your hardware list. We will assemble the declaration file — component-level, dated against the current Candidate List — before your order ships.

The Bottom Line
A REACH SVHC declaration is usable when it names the regulation and article, states the Candidate List revision it was checked against, gives a per-component result with substance, concentration and location, and shows the supplier’s own upstream diligence. Push back on lead, cadmium, hexavalent chromium and listed phthalates in accessible parts, keep the register current against list updates, and never accept “REACH compliant” as a result. The paperwork exists to be acted on — a file that only gets opened in an audit is a file that will not survive one.
Frequently Asked Questions
Is an SVHC above 0.1% illegal in my vanity hardware?
No. Presence above the threshold triggers communication duties under Article 33 and, for relevant EU-market articles, SCIP notification duties — it does not by itself prohibit sale. Restrictions are a separate mechanism. What matters is that the substance is named, quantified and explained, and that any applicable restriction is checked separately.
The supplier’s declaration says “all materials comply with REACH.” Is that enough?
No. It does not tell you whether Candidate List substances are present, which revision was checked, or at what level the assessment was made. Ask for a re-issued declaration that states the result per component against a dated Candidate List revision.
How often should I re-request SVHC declarations?
Whenever the Candidate List is updated and your parts could be affected, and whenever the supplier signals a change of material, plating or lubricant source. A twice-yearly review aligned to list updates, plus change-driven re-requests, keeps the file current without drowning the supplier in paperwork.
Do SVHC declarations replace the need for my own customer-facing compliance documents?
No — they feed them. Your own declarations, listings and any market-specific files are only as strong as the upstream data, which is why the substance, concentration and component fields in the supplier’s document matter. Treat the supplier declaration as an input to your compliance file, not as its substitute.